![Festo CMMT-ST-SW Скачать руководство пользователя страница 504](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377504.webp)
ID Px.
Parameters
Description
Bit mask for data trigger AND link
Access
read/write
Update
effective immediately
60013
Bit mask data trigger
Unit
−
Tab. 434 Parameters
Data trigger example
The recording should be started when the value of the following parameter exceeds 0.5 user units:
–
Setpoint value speed controller (ID P1.2216.0.0)
Parameter settings (example)
Parameters
Value
Value
Selection of the axis ID data trigger
P0.6000.0.0
1
1 = Axis 1
Selection of the data ID data trigger
P0.6001.0.0
2216
"Setpoint value speed controller" parameter as trigger sig-
nal
Selection of the data instance ID data trigger
P0.6002.0.0
0
Instance 0
Selection of the array ID data trigger
P0.6003.0.0
0
Array ID = 0
Selection of the trigger event configuration
P0.6004.0.0
1
1 = Rising edge
(exceeding the threshold value in a positive direction)
Selection of trigger threshold
P0.60012.0.0
0.5
Threshold value = 0.5 user units
Tab. 435 Parameter settings (example)
Parameters for configuring the trigger event for diagnostic triggers
ID Px.
Parameters
Description
Specifies the axis ID of the diagnostic event.
Access
read/write
Update
effective immediately
103100
Axis ID diagnostic
trace
Unit
−
Diagnostics and fault clearance