![Festo CMMT-ST-SW Скачать руководство пользователя страница 181](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377181.webp)
ID Px.
Parameters
Description
Digital output image CiA402
Access
read/write
Update
effective immediately
1128054
Digital outputs
CiA402
Unit
−
Tab. 150 Parameters
Parameters of digital inputs X1A.7, X1A.8 (Px.11201, Px.11202)
Value
Function
Description
1
No function
The input is deactivated.
3
Release holding brake 1
The input signal enables the functional release of one
or more holding brakes.
6
Touch probe 0
7
Touch probe 1
The input provides the trigger signal for the high-preci-
sion recording of the current actual position. The saved
values can be read out using the device profile used.
8
Negative hardware limit switch
9
Positive HW limit switch
The input shows the exceeding of the usable range in a
negative or positive direction. The switching function
can be set with parameters Px.101100 and Px.101101
(N/C or N/O contact). For more information, see
è
5.5 Hardware limit switch reached
11
Record table input 0
12
Record table input 1
The input can be used as a step enabling condition
during record selection (ID Px.1831 = 4).
Tab. 151 Configurable input signals at X1A.7 and X1A.8
Parameters of digital input X1C.2 (Px.11205)
Value
Function
Description
1
No function
The input is deactivated.
8
Negative hardware limit switch
9
Positive HW limit switch
The input shows the exceeding of the usable range in a
negative or positive direction. The switching function
can be set with parameters Px.101100 and Px.101101
(N/C or N/O contact). For additional information
è
5.5 Hardware limit switch reached.
10
Homing Switch
The input returns the signal of the reference switch.
Tab. 152 Configurable input signals at X1C.2
Product configuration
181
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......