ID Dx.
Message
Description
tion
Can be parameterised: Px.758, value list:
Stop category 0 (4096)
Stop category 1a (1024)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
internal (1)
Invalid (0)
Default: save (1)
08 | 04 | 00281
(134480153)
Process data not
received at Sync time
Error
memory
Can be parameterised: Px.759
The required application class is not supported
Remedy
–
Only request application class supported
by the device (see documentation)
Default: Warning (16)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 09 | 00144
(134807696)
Required application
class not supported
Error
memory
Can be parameterised: No
The required telegram is not supported
Remedy
–
Only request telegrams supported by the
device (see documentation)
Default: Warning (16)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 09 | 00145
(134807697)
The required telegram
is not supported
Error
memory
Can be parameterised: No
PROFIdrive test error message 1
Remedy
–
Retract test error message by PNU
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 09 | 00288
(134807840)
PROFIdrive test error
message 1
Error
memory
Can be parameterised: No
Diagnostics and fault clearance
476
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW