ID Px.
Parameters
Description
Specifies the limit value "maximum torque" for the symmetrical
torque limitation at the output of the velocity controller.
Access
read/write
Update
effective immediately
526796
Maximum torque sym-
metrical
Unit
Nm
Tab. 350 Parameters
ID Dx.
Name
Description
06 | 02 | 00086
(100794454)
Sign limits
Setpoint torque and velocity limit do not
match
Tab. 351 Diagnostic messages
6.1.3.1
CiA 402
Velocity controller objects
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
1210
0x606C.00
Actual velocity value
SINT32
526796
0x6072.00
Maximum torque symmetrical
UINT16
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
224
0x215B.05
Velocity controller amplification gain
FLOAT32
225
0x215B.06
Velocity controller integration constant
FLOAT32
1210
0x2155.0B
Actual velocity value
FLOAT32
2215
0x215B.07
Velocity control error
FLOAT32
2216
0x215B.08
Setpoint value velocity controller
FLOAT32
2218
0x215B.0A
Minimum torque
FLOAT32
2219
0x215B.0B
Maximum torque
FLOAT32
2220
0x215B.0C
Setpoint value torque
FLOAT32
52676
0x2152.0A
Current limitation active
BOOL
526796
0x2168.17
Maximum torque symmetrical
FLOAT32
Tab. 352 Objects
6.1.4
Current regulator
The current regulator consists of an active current regulator and a reactive current regulator which
specify the voltage setpoint values for the secondary power output stages.
Control
349
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......