ID Px.
Parameters
Description
Specifies the maximum winding temperature of the motor. When
the specified temperature threshold is exceeded, the corres-
ponding diagnostic message is generated with the paramet-
erised behaviour (temperature monitoring of motor).
Access
read/−
Update
reinitialization
7146
Winding temperature
Unit
°C
Specifies the nominal motor voltage of the motor.
Access
read/−
Update
reinitialization
7149
Nominal motor
voltage
Unit
V
Specifies the major version number of the hardware.
Access
read/−
Update
reinitialization
7150
Major version hard-
ware
Unit
−
Specifies the minor version number of the hardware.
Access
read/−
Update
reinitialization
7151
Minor version hard-
ware
Unit
−
Sensor type of temperature sensor.
Possible sensor types
è
Tab. 105 Value list of the temperature sensor parameters.
Access
read/−
Update
reinitialization
7152
Temperature sensor
Unit
−
Specifies the characteristic of the temperature sensor. The tem-
perature characteristic is described by a straight line resulting
from the gain (increase) and the offset.
Index 0: gain
Index 1: Offset
Access
read/−
Update
reinitialization
7155
Temperature sensor
characteristic
Unit
−