ID Px.
Parameters
Description
adapted to the inertia of the holding brake by parameters. The
position controller is switched off after expiration of the switch-
off delay. The holding brake should then be completely closed.
Access
read/−
Update
effective immediately
7166
Current switch-off
delay holding brake
Unit
s
Specifies the order code of the motor -> product labelling of the
motor.
Access
read/−
Update
effective immediately
7188
Current NOC code
motor
Unit
−
Specifies the nominal motor voltage of the motor -> data sheet
of the motor. An excessive DC link voltage can destroy the
motor!
Access
read/−
Update
effective immediately
71422
Current nominal
motor voltage
Unit
V
Specifies the effective current that the motor requires to apply
the stall torque -> data sheet of the motor.
Access
read/−
Update
effective immediately
71425
Current continuous
current
Unit
Arms
Specifies the currently used inductance orthogonal to the direc-
tion of the field. This value is a theoretical construct and cannot
be measured. -> data sheet of the motor.
Access
read/−
Update
effective immediately
71426
Current Lq inductance
Unit
H
Specifies the currently used inductance along the direction of
the field. This value is a theoretical construct and cannot be
measured. -> data sheet of the motor.
Access
read/−
Update
effective immediately
71427
Current Ld inductance
Unit
H
Product configuration