ID Px.
Parameters
Description
Specifies the currently used upper limit value for monitoring the
DC link voltage.
Access
read/−
Update
effective immediately
56800
Current upper limit
value DC link voltage
Unit
V
Specifies the currently used lower limit value for monitoring the
DC link voltage.
Access
read/−
Update
effective immediately
56801
Current lower limit
value DC link voltage
Unit
V
Tab. 169 Parameters of “Monitoring of the DC link voltage”
ID Dx.
Name
Description
02 | 02 | 00030
(33685534)
Overvoltage in intermediate cir-
cuit
Overvoltage in intermediate circuit
02 | 02 | 00031
(33685535)
Undervoltage in intermediate cir-
cuit
Undervoltage in intermediate circuit
02 | 02 | 00032
(33685536)
Intermediate circuit warning
threshold reached
Intermediate circuit warning threshold
reached
Tab. 170 Diagnostic messages of “Monitoring of the DC link voltage”
CiA 402
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
480
0x6079.00
Actual value DC link voltage
UINT32
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
480
0x2114.01
Actual value DC link voltage
FLOAT32
4811
0x2114.0A
Warning thresholds DC link voltage
FLOAT32
4813
0x2114.0C
Upper limit value DC link voltage
FLOAT32
4814
0x2114.0D
Lower limit value DC link voltage
FLOAT32
56799
0x2114.18
Current warning threshold DC link voltage
FLOAT32
56800
0x2114.19
Current upper limit value DC link voltage
FLOAT32
56801
0x2114.1A
Current lower limit value DC link voltage
FLOAT32
Tab. 171 Objects of “Monitoring of the DC link voltage”
Product configuration
196
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......