Parameter settings (example)
Parameters
Value
Comment
Selection of the axis ID trace data: Axis 1
P0.5501.0.0
1
Channel 0: Axis 1
P0.5501.0.1
1
Channel 1: Axis 1
Selection of the data ID trace data
P0.5502.0.0
4682
Channel 0, current position: following error
P0.5502.0.1
128
Channel 1, actual position value
Selection of the data instance ID trace data
P0.5503.0.0
0
Instance = 0
P0.5503.0.1
0
Instance = 0
Selection of the array ID trace data
5504.0.0
0
ArrayID = 0
5504.0.1
0
ArrayID = 0
Selection of the trace channels
5500.0.0
1
Activate trace channel 0
5500.0.1
1
Activate trace channel 1
Tab. 431 Parameter settings (example)
Trace and trigger configuration parameters
ID Px.
Parameters
Description
Specifies the trigger type.
This means:
–
0 = after start, immediate recording without trigger
–
1 = Data trigger (parameter as trigger signal)
–
2 = Diagnostic trigger (diagnostic event as trigger signal)
Access
read/write
Update
effective immediately
341
Trigger type
Unit
−
Specifies the status of the measuring data recording.
This means:
–
0 = Recording inactive (idle)
–
1 = Recording active, wait for trigger signal
–
2 = Recording started
556
Data trace status
Access
read/−
Diagnostics and fault clearance