![Festo CMMT-ST-SW Скачать руководство пользователя страница 407](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377407.webp)
7.1.2
CiA 402
Cam controller objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
112700
0x2192.01
Cam controller mode
UINT16
112701
0x2192.03
Cam controller source
UINT16
112702
0x2192.05
Upper limit value modulo
SINT64
112703
0x2192.07
Lower limit value modulo
SINT64
112704
0x2192.09
Inactive time compensation of first switching
point
FLOAT32
112705
0x2192.0B
Inactive time compensation of second switch-
ing point
FLOAT32
112706
0x2192.0D
Hysteresis
SINT64
112707
0x2192.0F
Switching time (manual)
FLOAT32
112708
0x226F.01 ... 04
Selection of switching function
UINT16
112709
0x2270.01 ... 04
Selection of switching characteristics
UINT16
112710
0x2271.01 ... 04
First switching point
SINT64
112711
0x2272.01 ... 04
Second switching point
SINT64
112712
0x2273.01 ... 04
Switching time (automatic)
FLOAT32
112713
0x2192.11
Current cam controller mode
UINT16
112714
0x2192.13
Current cam controller source
UINT16
112715
0x2192.15
Current upper limit value modulo
SINT64
112716
0x2192.17
Current lower limit value modulo
SINT64
112717
0x2192.19
Current inactive time first switching point
FLOAT32
112718
0x2192.1B
Current inactive time second switching point
FLOAT32
112719
0x2192.1D
Current hysteresis
SINT64
112720
0x2192.1F
Current switching time (manual)
FLOAT32
112721
0x2274.01 ... 04
Current selection of switching function
UINT16
112722
0x2275.01 ... 04
Current selection of switching characteristics
UINT16
112723
0x2276.01 ... 04
Current first switching point
SINT64
112724
0x2277.01 ... 04
Current second switching point
SINT64
112725
0x2278.01 ... 04
Current switching time (automatic)
FLOAT32
112726
0x2192.21
Modulo position for the logic (ON)
SINT64
Technology functions