Specifies the positive stroke limit. The positive stroke limit must
be greater than the negative stroke limit.
Access
read/write
Update
effective immediately
10369
Default value positive
stroke limit
Unit
user defined
Specifies whether automatic braking should be activated. If
automatic braking is active, the drive is decelerated so that it
stops before the stroke limit, if possible. If automatic braking is
deactivated, the drive is only stopped once it reaches the stroke
limit.
0: inactive
1: active
Access
read/write
Update
effective immediately
4675
Activation of automat-
ic stop ramp stroke
limit
Unit
−
Tab. 320 Parameters - Stroke limit reached
ID Dx.
Name
Description
07 | 01 | 00119
(117506167)
Negative stroke limit reached
Negative stroke limit reached
07 | 01 | 00120
(117506168)
Positive stroke limit reached
Positive stroke limit reached
Tab. 321 Diagnostic messages - Stroke limit reached
5.9.1
CiA 402
Objects - Stroke limit reached
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
10368
0x2190.08
Default value negative stroke limit
SINT64
10369
0x2190.09
Default value positive stroke limit
SINT64
4675
0x2166.3D
Activation of automatic stop ramp stroke limit BOOL
Tab. 322 Objects
Motion monitoring
333
Festo — CMMT-ST-SW — 2019-02