ID Dx.
Message
Description
Undervoltage in mains voltage
Remedy
–
Checking the power supply
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: Px.519, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: save (1)
02 | 03 | 00038
(33751078)
Undervoltage in
mains voltage
Error
memory
Can be parameterised: Px.5180
Overvoltage in mains voltage
Remedy
–
Checking the power supply
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
02 | 03 | 00039
(33751079)
Overvoltage in mains
voltage
Error
memory
Can be parameterised: No
The limit value for the energy recovery has been exceeded
Remedy
–
Checking the power supply
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
02 | 03 | 00251
(33751291)
Limit value of energy
recovery exceeded
Error
memory
Can be parameterised: No
Warning threshold: Temperature in device too low
Remedy
–
Check ambient conditions
Default: Warning (16)
Classifica-
tion
Can be parameterised: No
Default: save (1)
03 | 01 | 00044
(50397228)
Warning threshold:
Temperature in device
too low
Error
memory
Can be parameterised: No
Diagnostics and fault clearance
447
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW