ID Px.
Parameters
Description
Specifies whether the motor has an integrated holding brake.
–
0: inactive, holding brake not available
–
1: active, holding brake available
Access
read/−
Update
reinitialization
7158
Holding brake
Unit
−
Switch-on delay saved in the EEPROM for the execution of a
command if an electronic data sheet for the Festo motor is
stored.
Access
read/−
Update
reinitialization
7161
Switch-on delay hold-
ing brake
Unit
s
The delay saved in the EEPROM for the deactivation of the regu-
lator if an electronic data sheet for the Festo motor is stored.
Access
read/−
Update
reinitialization
7164
Switch-off delay hold-
ing brake
Unit
s
Specifies the effective current that the motor requires to apply
the stall torque.
Access
read/−
Update
reinitialization
7181
Continuous current
Unit
Arms
Specifies the ID of the encoder data set.
Access
read/−
Update
reinitialization
7183
Encoder data set ID
Unit
−
Specifies the major version of the motor data set.
Access
read/−
Update
reinitialization
7186
Major version motor
data set
Unit
−
Product configuration
137
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW