ID Px.
Parameters
Description
Update
effective immediately
1818
Record table field 7
Unit
−
Specifies the behaviour on switching to another command
record.
This means:
–
0: interrupt
è
The current command is interrupted immediately, and the
newly addressed command is executed directly.
–
1: wait
è
The current command is completed. The subsequent com-
mand addressed by the last start signal is only started after
the current command has been completed.
–
2: ignore
è
The start command is ignored. The current command is
completed. A new record can only be started after the MC is
active (new start signal required).
Access
read/write
Update
effective immediately
1838
Selection start condi-
tion record
Unit
−
Display the status of the current record.
–
0: Inactive
–
1: new
–
2: active
–
3: executed
–
5: buffered
–
6: cancelled
–
7: synchronised
Access
read/−
Update
effective immediately
1846
Status of record table
Unit
−
Tab. 261 Parameters
Parameters depending on the record type
The meaning of the record table field 1 … record table field 7 parameters depends on the selected
record type (value of the record type parameter).