In user parameter sets, parameters are always saved in the unit set by the user. When a user unit is
set, the derived variable obtains the same length reference (m, m/s, m/s
2
, etc.).
Parameters for the configurable measuring units
ID Px.
Parameters
Description
Specifies the active user unit.
Access
read/−
Update
effective immediately
1150
Current user unit
Unit
−
Selection of the next user unit
–
0: Internal increments [Inci, Inci/s, …]
–
1: Increments [Inc, Inc/s, …]
–
2: Rev [rev, rps, …]
–
3: Rev [rev, rpm, …]
–
4: Rad [rad, rad/s, …]
–
5: Degree [°, °/s, …]
–
6: Metric [m, m/s, …]
–
7: Imperial [in, in/s, …]
Access
read/write
Update
reinitialization
1151
Selection of next user
unit
Unit
−
Specifies whether the user unit is active
Access
read/−
Update
effective immediately
1152
User unit status
Unit
−
Tab. 90 Parameters
CiA 402
Objects for the configurable measuring units
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
1150
0x217C.01
Current user unit
UINT32
1151
0x217C.02
Selection of next user unit
UINT32
1152
0x217C.03
User unit status
UINT32
Tab. 91 Objects