![Festo CMMT-ST-SW Скачать руководство пользователя страница 499](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377499.webp)
ID Px.
Parameters
Description
Update
effective immediately
5500
Trace channel
Unit
−
Specifies the axis ID of the signal that should be recorded. The
array ID is used for the channel assignment.
5501.0.0: channel 0
…
5501.0.n: channel n
Access
read/write
Update
effective immediately
5501
Axis ID trace data
Unit
−
Specifies the data ID of the signal to be recorded. The array ID is
used for the channel assignment.
5502.0.0: channel 0
…
5502.0.n: channel n
Access
read/write
Update
effective immediately
5502
Data ID trace data
Unit
−
Contains the instance number of the signal to be recorded. The
array ID is used for the channel assignment.
5503.0.0: channel 0
…
5503.0.n: channel n
Access
read/write
Update
effective immediately
5503
Data instance ID trace
data
Unit
−
Contains the array ID of the signal to be recorded. The array ID is
used for the channel assignment.
5504.0.0: channel 0
…
5504.0.n: channel n
Access
read/write
Update
effective immediately
5504
Array ID trace data
Unit
−
Tab. 430 Parameters
Example
The following measured values of axis 1 should be recorded at the same time:
–
Storage option in error log (P1.4682.0.0) to channel 0
–
Actual position value (P1.128.0.0) to channel 1