Parameters
Index.Subindex
Name
Data type
8411
0x2172.0C
Search for move to axis zero point setpoint
jerk
FLOAT32
8412
0x2172.0D
Maximum search stroke in positive direction
SINT64
8413
0x2172.0E
Maximum search stroke in negative direction
SINT64
8414
0x2172.0F
Nominal current limit value scaling factor
FLOAT32
8415
0x2172.10
Limit position detection time monitoring win-
dow
FLOAT32
8416
0x2172.11
Axis zero point offset
SINT64
8417
0x2172.12
Referencing method
SINT32
8418
0x2172.13
Status state machine homing
UINT32
8421
0x2172.16
Deactivate encoder emulation during homing
BOOL
Tab. 255 Objects
The overview shows the function of the homing mode:
Fig. 67 Overview: homing mode