![Festo CMMT-ST-SW Скачать руководство пользователя страница 482](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377482.webp)
ID Dx.
Message
Description
An error has occurred when changing the user unit
Remedy
–
Run reinitialisation again
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 01 | 00163
(184615075)
User unit error
Error
memory
Can be parameterised: Px.11590
The supply voltage to the communication module dropped
Remedy
–
Checking the power supply
–
Restart device
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 01 | 00244
(184615156)
Communication mod-
ule supply voltage
Error
memory
Can be parameterised: No
Process runtime exceeded
Remedy
–
internal error, service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 02 | 00164
(184680612)
Process runtime
exceeded
Error
memory
Can be parameterised: No
Timeout has occurred in process level 0
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 02 | 00165
(184680613)
Timeout process
level 0
Error
memory
Can be parameterised: No
Timeout has occurred in process level 1
Remedy
–
Service required
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 02 | 00166
(184680614)
Timeout process
level 1
Error
memory
Can be parameterised: No
Diagnostics and fault clearance
482
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......