Trace and trigger configuration objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
341
0x210F.02
Trigger type
UINT32
556
0x2117.01
Data trace status
UINT32
557
0x2117.02
Recording delay
SINT32
558
0x2117.03
Recording length
UINT32
559
0x2117.04
Down sampling factor
UINT32
5516
0x2117.08
Maximum recording length
UINT32
5517
0x2117.09
Basic sampling interval
FLOAT32
Tab. 439 Objects
Objects for configuring the trigger event for data triggers
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
6000
0x211B.01
Axis ID data trigger
UINT16
6001
0x211B.02
Data ID data trigger
UINT32
6002
0x211B.03
Data instance ID data trigger
UINT16
6003
0x211B.04
Array ID data trigger
UINT16
6004
0x211B.05
Trigger event
UINT32
60012
0x211B.0C
Trigger level
SINT64
60013
0x211B.0D
Bit mask data trigger
UINT64
Tab. 440 Objects
Objects for configuring the trigger event for diagnostic triggers
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
103100
0x2142.01
Axis ID diagnostic trace
UINT16
103101
0x2142.02
Diagnostics ID diagnostic trace
UINT32
103102
0x2142.03
Data instance ID diagnostic trace
UINT16
103103
0x2142.04
Current axis ID diagnostic trace
UINT16
103104
0x2142.05
Current diagnostics ID diagnostic trace
UINT32
103105
0x2142.06
Current data instance ID diagnostic trace
UINT16
Diagnostics and fault clearance
507
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......