ID Px.
Parameters
Description
Specifies the numerator of the gear ratio for the first gear unit
(drive side).
Access
read/write
Update
effective immediately
1232
Conversion factor
gear unit 1 numerator
Unit
−
Specifies the denominator of the gear ratio for the first gear unit
(output side).
Access
read/write
Update
effective immediately
1233
Conversion factor
gear unit 1 denomin-
ator
Unit
−
Specifies the database ID of the second gear unit.
Access
read/write
Update
effective immediately
1234
Database ID gear unit
2
Unit
−
Specifies the order code of the second configured gear unit.
Access
read/write
Update
effective immediately
1235
NOC code gear unit 2
Unit
−
Specifies the numerator of the gear ratio for the second gear
unit (drive side).
Access
read/write
Update
effective immediately
1236
Conversion factor
gear unit 2 numerator
Unit
−
Specifies the numerator of the gear ratio for the second gear
unit (output side).
Access
read/write
Update
effective immediately
1237
Conversion factor
gear unit 2 denomin-
ator
Unit
−
Specifies the database ID of the third gear unit.
Access
read/write
Update
effective immediately
1238
Database ID gear unit
3
Unit
−
Product configuration
176