ID Dx.
Message
Description
PROFIdrive test error message 2
Remedy
–
Retract test error message by PNU
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 09 | 00289
(134807841)
PROFIdrive test error
message 2
Error
memory
Can be parameterised: No
The PLC control bit is not set
Remedy
–
Set PLC control bit (STW1.bit10)
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: Px.11280117, value
list:
Stop category 0 (4096)
Stop category 1a (1024)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
internal (1)
Invalid (0)
Default: save (1)
08 | 09 | 00294
(134807846)
PLC Control is not set
Error
memory
Can be parameterised: Px.11280118
An invalid mode of operation was requested
Remedy
–
Check requested CiA402 operating mode
Default: Stop category 2 (64)
Classifica-
tion
Can be parameterised: Px.12236, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: save (1)
08 | 12 | 00250
(135004410)
Invalid mode of oper-
ation
Error
memory
Can be parameterised: Px.12237
Diagnostics and fault clearance
477
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW