Index.
Subindex
Name
Data type
Access
PDO map-
ping
Parameter
0x217B.0F
Interpolation mode CST
UINT32
rw
Rx
P1.11414.0.0
0x217B.12
Timing tolerance
SINT32
ro
Tx
P1.11417.0.0
0x217B.13
Interpolation step loss
counter
SINT32
ro
Tx
P1.11418.0.0
0x217C.01
Current user unit
UINT32
ro
Tx
P1.1150.0.0
0x217C.02
Selection of next user unit
UINT32
rw
Rx
P1.1151.0.0
0x217C.03
User unit status
UINT32
ro
Tx
P1.1152.0.0
0x217C.04
Current torque constant
FLOAT32
ro
Tx
P1.1153.0.0
0x217C.05
Current pole pairs
UINT32
ro
Tx
P1.1154.0.0
0x217C.06
Diagnostic category
UINT16
ro
Tx
P1.1159.0.0
0x217C.07
Storage option in error log
UINT8
rw
Rx
P1.11590.0.0
0x217D.01
Reversing the direction of
rotation
BOOL
rw
Rx
P1.1170.0.0
0x217D.02
Phase rotation
BOOL
rw
Rx
P1.1172.0.0
0x217D.03
Reversing the direction of
rotation validation status
BOOL
rw
Rx
P1.1173.0.0
0x217D.04
Validation status of phase
rotation
BOOL
rw
Rx
P1.1175.0.0
0x217E.01
Database ID of axis
UINT32
rw
Rx
P1.1191.0.0
0x217E.02
Axis NOC code
STRING(50)
rw
Rx
P1.1192.0.0 ... 49
0x217E.03
Load weight / load inertia
FLOAT32
rw
Rx
P1.1193.0.0
0x217E.04
Feed constant numerator
UINT32
rw
Rx
P1.1194.0.0
0x217E.05
Feed constant denominator UINT32
rw
Rx
P1.1195.0.0
0x217E.06
Working stroke
SINT64
rw
Rx
P1.1196.0.0
0x217E.07
Design axis
UINT32
rw
Rx
P1.1197.0.0
0x217E.08
Length connecting shaft
FLOAT32
rw
Rx
P1.1198.0.0
0x217E.09
Maximum driving torque
axis
FLOAT32
rw
Rx
P1.1199.0.0
0x217E.0A
Unlimited axis
BOOL
rw
Rx
P1.2424.0.0
0x217F.01
Database ID of mounting
kit
UINT32
rw
Rx
P1.1200.0.0
0x217F.02
NOC code mounting kit
STRING(37)
rw
Rx
P1.1201.0.0 ... 36
EtherCAT
590
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW