Diagnostic level
Colour display
Stop category 1
Tab. 50 Description of possible diagnostic levels
Transferring warnings to the diagnostic memory
Diagnostic messages that have been classified as warnings can be written to the diagnostic memory
with the "error log" checkbox above the table.
The checkbox can have the following statuses:
Status
Description
There are various settings. Some messages that have been classified as
warnings are written to the diagnostic memory, others are not.
All messages that have been classified as warnings are written to the dia-
gnostic memory.
All messages that have been classified as warnings are not written to the
diagnostic memory.
Tab. 51 Description of the statuses of the "error log"checkbox
Switching to the "Error log" panel
Actuating the "Go to diagnosis page "Error Log"" button via the table opens the "Error log" dia-
gnostics panel.
2.4.6
Trace configuration
The working area contains parameter groups to configure a trace recording.
All available device parameters can be recorded. Recordings enable the system behaviour to be mon-
itored and optimised and possible errors to be identified.
Recording channels can be created, edited and deleted in the "Trace channels" parameter group.
Additional information on recording measurement data
è
9.5 Recording measuring data (trace).
Creating a new recording channel
New recording channels can be created with the "Add new trace channel" button.
The button is only active if the following prerequisite is met:
–
The maximum number of trace channels has not been created yet.
1. Actuate "Add new trace channel" button.
Ä
The pop-up to create a recording channel is opened.
A direct search for a device parameter can be completed via the search field using the ID,
name or description.
CMMT-ST Plug-in
83
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW