Learning Advanced Features
192
Multi-Function Output On/Off Control
Activates the multi-function outputs (Relay1 or Q1) based on an analog input level. Both On (closed)
and Off (open) levels can be set.
Group
Code
Name
LCD Display
Parameter Setting Setting Range
Unit
OU
67
Output terminal
on/off control
mode
On/Off Ctrl
Src
1
V1
-
-
68
Output terminal
on level
On-C Level
90.00
Output
terminal off
level
–
100.00%
%
69
Output terminal
off level
Off-C Level
10.00
0.00
–
Output
terminal on
level
%
OU
31
Multi-function
relay1 item
Relay 1
34
On/Off
-
-
33
Multi-function
output1 item
Q1 Define
Multi-function Output On/Off Control Setting Details
Code
Description
OU.67 On/Off Ctrl Src
Select the source of the analog input for On/Off control.
OU.68 On-C Level ,
OU.69 Off-C Level
Set On/Off level for the multi-function output terminal.
Ad.44, 45
Ad.47
Ad.41
Ad.42
Ad.15
Ad.46
Output frequency
Output current
Motor speed
Brake output
Run cmd
Brake close
Brake open