Learning Advanced Features
50
Initializing All Parameters
The following example demonstrates parameter initialization using code dr.93 (Parameter
Initialization) in the Drive group. Once executed, parameter initialization will delete all modified
values for all codes and groups.
Step
Instruction
Keypad Display
1
Go to code 0 (Jog Frequency) in the Drive group.
2
Press the [ENT] key.
The current parameter value (9) will be displayed. (default
setting)
3
Press the [
▼
] key to change the ones place to ‘3’ of the target
code, ’93.’
4
Press the [
◀
] key to move to the tens place.
‘
03’ will be displayed.
5
Press the [
▲
] or [
▼
] key to change the
‘
0
’
to
‘
9
’
of the target
code,
’
93.
’
6
Press the [ENT] key.
Code dr.93 will be displayed.
7
Press the [ENT] key once again.
The current parameter value for code dr.93 is set to 0 (Do not
initialize).
8
Press the [
▲
] key to change the value to 1 (All Grp), and then
press the [ENT] key.
The parameter value will flash.
9
Press the [ENT] key once again.
Parameter initialization begins. Parameter initialization is
complete when code dr.93 reappears on the display.
Note
Following parameter initialization, all parameters are reset to factory default values. Ensure that
parameters are reconfigured before running the inverter again after an initialization.
ENT
ENT
OR
OR
DR.93
)
!
DR. 0
(
)3
#
(3
dr.0
9
3
03
93
dr.93
0
1
dr.93
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......