Installing the Inverter
28
Function
Label
Name
Description
•
Maximum Voltage Output: 12V
•
Maximum Current Output:
100mA,
•
Potentiometer: 1–5kΩ
V1
Voltage input for frequency
reference input
Used to setup or modify a frequency
reference via analog voltage input
terminal.
•
Unipolar: 0–10V (12V Max.)
•
Bipolar: -10–10V (±12V Max.)
I2
Voltage/current input for
frequency reference input
Used to setup or modify a frequency
reference via analog voltage or
current input terminals.
Switch between voltage (V2) and
current (I2) modes using a control
board switch (SW2).
V2 Mode:
•
Unipolar: 0–10V (12V Max.)
I2 Mode
•
Input current: 4–20mA
•
Maximum Input current: 24mA
•
Input resistance: 249Ω
TI
Pulse input for frequency
reference input (pulse train)
Setup or modify frequency
references using pulse inputs from 0
to 32kHz.
•
Low Level: 0–2.5V
•
High Level: 3.5–12V
(For Standard I/O, Pulse input TI and
Multi-function terminal P5 share the
same terminal. Set the ln.69 P5
Define to 54(TI).).
Safety functionality
configuration
SA
Safety input A
Used to block the output from the
inverter in an emergency.
Conditions:
•
Normal Operation: Both the SA
and SB terminals are connected
to the SC terminal.
•
Output Block: One or both of
the SA and SB terminals lose
connection with the SC
terminal.
SB
Safety input B
SC
Safety input power source
DC 24V, < 25mA
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......