Learning Advanced Features
59
4
Learning Basic Features
This chapter describes the basic features of the ”S” Series inverter. Check the reference page in the
table to see the detailed description for each of the advanced features.
Basic Tasks
Description
Ref.
Frequency reference source
configuration for the keypad
Configures the inverter to allow you to setup or modify
frequency reference using the Keypad.
p.62
Frequency reference source
configuration using V1 or V2
Configures the inverter to allow input voltages at terminals
V1 or V2 to control the frequency reference.
p.63
,
p.70
Frequency reference source
configuration using I2
Configures the inverter to allow input currents at terminal
I2 to control the frequency reference.
p.68
Frequency reference source
configuration using TI
terminal (pulse input)
Configures the inverter to allow an input pulse at the
terminal TI to control the frequency reference.
p.71
Frequency reference source
configuration using RS-485
communication
Configures the inverter to allow communication signals
from controllers, such as PLCs or PCs, to setup or modify a
frequency reference.
p.73
Frequency hold control when
using analog inputs
Enables the user to hold a frequency steady with a digital
input when using analog inputs at terminals.
p.74
Motor speed display options
Motor speed is displayed either in frequency (Hz) or speed
(rpm).
p.74
Multi-step speed (frequency)
configuration
Configures multi-step frequencies using digital inputs at the
terminals defined for each step frequency.
p.75
Command source
configuration for keypad
buttons
Configures inverter operation using the [FWD], [REV] and
[Stop] keys on the keypad.
p.77
Command source
(Start/Stop) configuration for
terminal inputs
Configures inverter start/stop operation using digital inputs
at the FX/RX terminals.
p.77
Command source
configuration for RS-485
communication
Configures inverter operation from communication signals
from controllers, such as PLCs or PCs.
p.79
Local/remote switching via
the [ESC] key
Configures the inverter to switch between local and remote
operation modes when the [ESC] key is pressed.
When the inverter is operated using remote inputs (any
input other than from the keypad), this configuration can
be used to control the inverter from the keypad without
altering saved parameter settings. It overrides the remote
settings to control the inverter from the keypad in
emergency situations.
p.79
Motor rotation (direction)
control
Configures the inverter to prevent operating the motor in a
specific direction.
p.81
Automatic start-up at power-
on
Configures the inverter to start operating at power-on.
With this configuration, the inverter begins to run and the
p.81
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......