RS-485 Communication Features
235
Group
Code
Name
LCD Display
Parameter Setting
Setting range
Unit
loss
14
Operation
frequency at
speed
command
loss
Lost Preset F 0.00
Start frequency–
Maximum
frequency
Hz
OU
31
Multi-
function
relay 1
Relay 1
13
Lost
Command
0-35
-
33
Multi-
function
output 1
Q1 Define
Group
Code
Name
LCD Display
Parameter
Setting
Setting
range
Unit
Operation
DRV
Command
source
Cmd
Source*
3
Int 485
0-5
-
Frq
Frequency
setting method
Freq Ref Src 6
Int 485
0-12
-
* Displayed in DRV-06 on an LCD keypad.
Command Loss Protective Operation
Configure the command loss decision standards and protective operations run when a
communication problem lasts for a specified period of time.
Command Loss Protective Operation Setting Details
Code
Description
Pr.12 Lost Cmd
Mode,
Pr.13 Lost Cmd Time
Select the operation to run when a communication error has occurred and
lasted exceeding the time set at Pr. 13.
Setting
Function
0
None
The speed command immediately becomes the
operation frequency without any protection
function.
1
Free-Run
The inverter blocks output. The motor performs in
free-run condition.
2
Dec
The motor decelerates and then stops at the time
set at Pr.07 (Trip Dec Time).
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......