223
Learning Protection Features
Do not select a resistor with a power rating lower than that specified in 11.7. If the resistor is
overloaded, it can overheat and cause a fire. When using a resistor with a thermal switch, the switch
can be used as an external trip input signal to the inverter.
Under load Fault Trip and Warning
Group
Code
Name
LCD
Display
Parameter Setting
Setting
range
Unit
Pr
04
Load level
selection
Load Duty 0
Normal
Duty
-
-
25
Under
load
warning
selection
UL Warn
Sel
1
Yes
0-1
-
26
Under
load
warning
time
UL Warn
Time
10.0
0-600
sec
27
Under
load trip
selection
UL Trip Sel 1
Free-Run -
-
28
Under
load trip
timer
UL Trip
Time
30.0
0-600
sec
29
Under
load upper
limit level
UL LF
Level
30
10-100
%
30
Under
load lower
limit level
UL BF
Level
30
10-100
%