Technical Specification
352
•
The standard motor capacity is based on a standard 4-pole motor.
•
The standard used for 200 V inverters is based on a 240 V supply voltage, and for 400V
inverters is based on a 480 V supply voltage.
•
The rated output current is limited based on the carrier frequency set at Cn.04.
•
The output voltage becomes 20~40% lower during no-load operations to protect the
inverter from tripping on OCT faults when the load returns (0.4~4.0kW models only).