170
Group
Code
Name
LCD
Display
Parameter Setting
Unit
maximu
m analog
input
100%
CNF*
21
Monitor
mode
display 1
Monitor
Line-1
1
Speed
22
Monitor
mode
display 2
Monitor
Line-2
2
Output
Current
23
Monitor
mode
display 3
Monitor
Line-3
3
Output
Voltage
*Available on LCD keypad only.
Torque reference setting details
Code
Description
dr-08
Select an input method to use as the torque reference.
Parameter Setting
Description
0
Keypad-1
Sets the torque reference with the
keypad.
1
Keypad-2
2,4,5
V1,V2,I2
Sets the torque reference using the
voltage or current input terminal of
the terminal block.
6
Int 485
Sets the torque reference with the
communication terminal of the
terminal block.
8
FieldBus
Input the torque reference using the
inverter's FieldBus option.
9
UserSeqLink
Enters torque reference by linking
common area with the user
sequence output.
12
Pulse
Input the torque reference using the
pulse input on the inverter's
terminal block.
Cn-02
The torque reference can be set up to 180% of the maximum rated motor
torque.
In-02
Sets the maximum torque. You can view the torque reference in Monitor (MON)
mode. Set one of CNF.21 ~ CNF.23.
CNF-21–
23
Select a parameter from the Config (CNF) mode and then select(19 Torque Ref).
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......