275
Table of Functions
Code
Comm.
Address
Name
LCD Display Setting Range
Initial
Value
Property
*
V/F SL Ref.
integral gain
28
32
0h141C
Speed estimator
proportional gain
S-Est P
Gain1
0-32767
O/A X
I
p.150
29
32
0h141D
Speed estimator
integral gain1
S-Est I Gain1 100-1000
O/A X
I
p.150
30
32
0h141E
Speed estimator
integral gain2
S-Est I Gain2 100-10000
O/A X
I
p.150
31
32
0h141F
Sensorless
current controller
proportional gain
ACR SL
P Gain
10-1000
O/A X
I
p.150
32
32
0h1420
Sensorless
current controller
integral gain
ACR SL I
Gain
10 -1000
O/A X
I
p.150
33
33
0h1421
PM D-axis back-
EMF estimation
gain [%]
PM EdGain
Perc
0~300.0[%]
100.0
X/A
X
P
34
33
0h1422
PM Q-axis back-
EMF estimation
gain [%]
PM EqGain
Perc
0~300.0[%]
100.0
X/A
X
P
35
33
0h1423
Initial pole position
detection retry
number
PD Repeat
Num
0~10
2
X/A
X
P
36
33
0h1424
Initial pole position
detection pulse
interval
Pulse
Interval
1~100
20
X/A
X
P
37
33
0h1425
Initial pole position
detection current
level [%]
Pulse Curr %
10~100
15
X/A
X
P
38
33
0h1426
Initial pole position
detection voltage
level [%]
Pulse Volt %
100~4000
500
X/A
X
P
39
33
0h1427
PM dead time
range [%]
PMdeadBan
d Per
50.0~100.0
100.0
X/A
X
P
40
33
0h1428
PM dead time
voltage [%]
PMdeadVolt
Per
50.0~100.0
100.0
X/A
X
P
41
33
0h1429
Speed estimator P
gain1
PM SpdEst
Kp
0~32000
100
X/A
X
P
42
33
0h142A
Speed estimator I
gain1
PM SpdEst
Ki
0~32000
10
X/A
X
P
43
33
0h142B
Speed estimator P
gain2
PM SpdEst
Kp 2
0~32000
300
X/A
X
P
33
Displayed when dr.09 (Control Mode) is set to 6 (PM Sensorless).
Содержание Rsi S Series
Страница 2: ......
Страница 6: ......
Страница 12: ...Preparing the Installation 0...
Страница 22: ...Preparing the Installation 10...
Страница 70: ...LearningAdvanced Features 58...
Страница 152: ...LearningAdvanced Features 140 PID controlblock diagram...
Страница 224: ...LearningAdvanced Features 212...
Страница 356: ...344...
Страница 362: ...Maintenance 350...
Страница 381: ...369 TechnicalSpecification...
Страница 397: ......