14. Dot Matrix LCD Controller (H8/3854 Group)
Rev.3.00 Jul. 19, 2007 page 396 of 532
REJ09B0397-0300
14.3.8 Power-On
and
Power-Off Procedures
As the LCD controller incorporates a complete power supply circuit, the procedures shown in
figure 14.10 must be followed when powering on and off. Failure to follow these procedures may
result in an abnormal display.
Starting
display
Halting
display
Write data
Set LPS1
*
, LPS0
*
, and DISP to 1
Clear LPS1, LPS0, and DISP to 0
Set DDTY1 according to mode used
Note:
*
Do not set to 1 when an external power supply is used.
Figure 14.10 Power-On and Power-Off Procedures
14.3.9
Power Supply Circuit
The LCD controller has a built-in bleeder resistance circuit for LCD drive. In standby mode, the
voltage circuits are automatically turned off and the power consumption of the power supply
circuit falls to zero. The power supply circuit can be turned on and off by a command, and an
external power supply circuit should be used if the current capacity of the built-in step-up circuit is
insufficient.
LCD Drive Level
Six power supply levels
⎯
V1, V2, V3, V3, V4, V5, and V
SS
⎯
are necessary for LCD drive. The
V1 to V
SS
power supplies are normally generated by means of resistive division.
When 1/4 bias is used for LCD display, the V3OUT and V4OUT pins should be shorted; when 1/5
bias is used, the V3OUT and V4OUT pins should be left open.
Summary of Contents for F-ZTAT H8 Series
Page 6: ...Rev 3 00 Jul 19 2007 page iv of xxiv REJ09B0397 0300...
Page 194: ...7 RAM Rev 3 00 Jul 19 2007 page 168 of 532 REJ09B0397 0300...
Page 234: ...8 I O Ports Rev 3 00 Jul 19 2007 page 208 of 532 REJ09B0397 0300...
Page 274: ...9 Timers Rev 3 00 Jul 19 2007 page 248 of 532 REJ09B0397 0300...
Page 352: ...12 A D Converter Rev 3 00 Jul 19 2007 page 326 of 532 REJ09B0397 0300...
Page 561: ......