SCI3 operates as follows when receiving serial data in synchronous mode.
SCI3 synchronizes internally with the input or output of the serial clock and starts receiving.
Received data is set in RSR from LSB to MSB.
After data has been received, SCI3 checks to confirm that the value of bit RDRF is 0 indicating
that received data can be transferred from RSR to RDR. If this check passes, RDRF is set to 1 and
the received data is stored in RDR. At this time, if bit RIE in SCR3 is set to 1, an RXI interrupt is
requested. If an overrun error is detected, OER is set to 1 and RDRF remains set to 1. Then if bit
RIE in SCR3 is set to 1, an ERI interrupt is requested.
For the overrun error detection conditions and receive data processing, see table 10.15.
Note: Data receiving cannot be continued while a receive error flag is set. Before continuing the
receive operation it is necessary to clear the OER, FER, PER, and RDRF flags to 0.
Figure 10.18 shows a typical receive operation in synchronous mode.
Serial
clock
Serial
data
RDRF
OER
LSI
operation
User
processing
Bit 7
Bit 0
Bit 7
Bit 0
Bit 1
Bit 6
Bit 7
1 frame
1 frame
RXI request RDRF cleared
to 0
RXI request
Read data
from RDR
ERI request due
to overrun error
RDR data
not read
(RDRF = 1)
Overrun error
handling
Figure 10.18 Typical Receive Operation in Synchronous Mode
Summary of Contents for F-ZTAT H8 Series
Page 6: ...Rev 3 00 Jul 19 2007 page iv of xxiv REJ09B0397 0300...
Page 194: ...7 RAM Rev 3 00 Jul 19 2007 page 168 of 532 REJ09B0397 0300...
Page 234: ...8 I O Ports Rev 3 00 Jul 19 2007 page 208 of 532 REJ09B0397 0300...
Page 274: ...9 Timers Rev 3 00 Jul 19 2007 page 248 of 532 REJ09B0397 0300...
Page 352: ...12 A D Converter Rev 3 00 Jul 19 2007 page 326 of 532 REJ09B0397 0300...
Page 561: ......