15. Electrical Characteristics (H8/3857 Group)
Rev.3.00 Jul. 19, 2007 page 405 of 532
REJ09B0397-0300
(2) Power Supply Voltage vs. Operating Frequency Range
5.0
2.5
0.5
1.0
3.0
V
CC
(V)
• Active mode (high speed)
• Sleep mode (except CPU)
φ
(MHz)
4.0
5.5
625.0
500.0
312.5
62.5
3.0
V
CC
(V)
• Active mode (medium speed)
φ
(kHz)
4.0
5.5
16.384
19.200
8.192
9.600
4.096
4.800
3.0
V
CC
(V)
• Subactive mode
• Subsleep mode (except CPU)
• Watch mode (except CPU)
φ
SUB
(kHz)
4.0
5.5
*
*
*
Note:
*
In case of external clock only
}
*
(3) Analog Power Supply Voltage vs. A/D Converter Operating Range
5.0
2.5
0.5
3.0
AV
CC
(V)
AV
CC
(V)
• Active mode (high speed)
• Sleep mode (except CPU)
• Active mode (medium speed)
φ
(MHz)
4.0
5.5
625.0
500.0
312.5
62.5
3.0
φ
(kHz)
4.0
5.5
Summary of Contents for F-ZTAT H8 Series
Page 6: ...Rev 3 00 Jul 19 2007 page iv of xxiv REJ09B0397 0300...
Page 194: ...7 RAM Rev 3 00 Jul 19 2007 page 168 of 532 REJ09B0397 0300...
Page 234: ...8 I O Ports Rev 3 00 Jul 19 2007 page 208 of 532 REJ09B0397 0300...
Page 274: ...9 Timers Rev 3 00 Jul 19 2007 page 248 of 532 REJ09B0397 0300...
Page 352: ...12 A D Converter Rev 3 00 Jul 19 2007 page 326 of 532 REJ09B0397 0300...
Page 561: ......