SISPM1040-582-LRT   

Managed Hardened PoE++ Switch (8) 10/100/1000Base-T PoE++ 

Ports + (2) 100/1000Base-X SFP Slot 

Quick Start Guide 

See the 

Install

 

Guide

 for important 

Cautions

 and 

Warnings

, Features, 

Specs, Back and Front Panel, LEDs, DIP Switch Settings, RESET button, 

Installation, Mounting, Installing SFPs, Connecting Devices, DI/DO Relay, 

Grounding, Connecting P1 and P2, Power Supply, Initial Config, 

Troubleshooting, Warranty, PoE Modes, Compliance, and Tech Support.   

Warning and Caution - Proper Installation and Operation (English): These devices are open-type devices that are to be installed in an 

enclosure only accessible with the use of a tool, suitable for the environment. This equipment is suitable for use in Class I, Division 2, 

Groups A, B, C, and D or non-hazardous locations only. WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE 

OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.

 

Avertissement et mise en garde - Installation et fonctionnement corrects (français): Ces périphériques sont des périphériques de type 

ouvert qui doivent être installés dans un enceinte uniquement accessible à l'aide d'un outil, adapté à environnement.   

Cet équipement peut être utilisé dans la classe I, division 2, groupes A, B, C, et D ou des emplacements non dangereux seulement. 

AVERTISSEMENT - RISQUE D'EXPLOSION. NE PAS SE DÉCONNECTER LORSQUE LE CIRCUIT EST VIVANT OU À MOINS QUE LA ZONE NE SOIT 

LIBRE DE CONCENTRATIONS IGNIFIABLES.

 

Package Contents

: Verify you received one Switch with Terminal Block attached, one DB-9 to RJ-45 Cable, four adhesive 

rubber feet, this document, and one DIN Rail mount kit. 

Front Panel

:

 The SISPM1040-582-LRT front panel ports, LEDs, Power Input terminal block, DI/DO terminal block, 

CONSOLE port, DIP Switch, RESET button, and Ground screw. 

LED Indicators

: The front panel LEDs provide switch and Ring status. 

Power LEDs

 indicate if the switch is powered up 

correctly. 

System LED

: indicates if the system is ready or not ready. 

Alarm

 

LED

 indicates if the system is normal or not. 

Ring Master LED

 and 

Rapid Chain LED

 indicate if the Rapid Ring is ready. 

Port Status LEDs

 indicate the current status of 

each port. See the 

Install

 

Guide

 for details. 

DIP Switch for Ring Settings

: The two-position DIP switch is labeled 

RC

 (1) (Rapid Chain) and 

RM

 (2) (Ring 

Master). The DIP switch lets you avoid having to access the Web UI or CLI to configure a ring. See the 

Install

 

Guide

 for DIP switch setting details.  

RESET

 

Button

: To reset the switch press RESET for 2~7 seconds; the SYS LED blinks green; Port status LEDs are Off.   

To restore to defaults, press RESET for 7~12 seconds; the SYS LED blinks green; Port status LEDs are all ON. 

Installation

Caution

: The switch is an indoor device. If used with outdoor devices such as outdoor IP cameras or 

outdoor Wi-Fi APs, then it is strongly suggested to install a surge protector or surge suppressor to protect the switch. 

Compliant with 802.3at in Environment A when using an isolated power supply. For other apps, see the 

Install

 

Guide

These devices are open-type devices that are to be installed in an enclosure only accessible with the use of a tool, 

suitable for the environment. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-

hazardous locations only. “WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR 

UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS. Temperature code (T-Code) – T4.   

Grounding Screw

ATTENTION

This case must be earth grounded. No DC input may be earth grounded. Use Isolated 

Power Supply. 

Caution

The switch is intended to be grounded to a well-grounded mounting surface such as a metal 

plate. Install the grounding wire prior to connecting any other device to the Switch. 

CAUTION

: Be sure to disconnect the 

Switch from the power source before installing and wiring the device. 

Warning

Turn the power off before connecting or disconnecting modules or wires. The correct power supply voltage is 

listed on the product label. Check the voltage of your power source to make sure that you are using the correct voltage. 

Do NOT use a voltage greater than what is specified on the product label.   

Reviews: