7-35
H
Communications Board
·
The following Communications Boards are available.
Note
The RS-232C port can be used if an RS-422/485 conversion adapter is installed.
For ease of wiring, however, it is recommended that the RS-422/485 port be
used. The following information is for the RS-422/485 port.
Series
Communications Board
model
Mounting method
Specifications
SYSMAC CS1
Series
CS1W-SCB41
As an inner board
of the CPU Unit
·
One RS-232C
port
·
One RS-422/485
port
·
Protocol macro
function
SYSMAC
C200HX/HG/HE
C200HW-COM06-EV1
Note
Make sure that the
model number has
the suffix “EV1,”
otherwise the
CRC-16 check
code cannot be
used.
Mounted to an
optional slot of the
CPU Unit
·
One RS-232C
port
·
One RS-422/485
port
·
Protocol macro
function
H
Peripheral Devices
·
The following peripheral devices are required to use the protocol macro function.
Name
Model
Specification
CX-Protocol WS02-PSTC1-E The following peripheral devices support the protocol
macro function of the SYSMAC CS1 Series.
Personal computer environment
Personal
computer
IBM PC/AT or compatible computer
CPU
Minimum requirement: Pentium 90 MHz
Recommended: Pentium 166 MHz or
faster
OS
Microsoft Windows 95 or Windows 98
Memory
Minimum: 16 MB
Recommended: 24 MB min.
Hard disk
Minimum: Available space of 24 MB
Recommended: Available space of 50 MB
Monitor
SVGA or better
Drive
FDD: 1 or more
CD-ROM drive: 1 or more
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...