7-26
Note 2.
No data can be written to multi-function input.
Note 3.
The unit of setting of the broadcast message is different from that in the DSR
message to communicate with a single Slave.
D
RUN Command (Register 0001 Hex)
Bit No.
Function
0
RUN command (1: RUN)
1
Forward/Reverse (1: Reverse)
2
External fault (1: External fault EF0)
3
Fault reset (1: Fault reset)
4 to 15
Not used
7-6-2 Monitor Functions
Register No.
(Hex)
Function
Description
0020
Status signal
Refer to the following corresponding table.
0021
Fault status 1
Refer to the following corresponding table.
0022
Data link status
Refer to the following corresponding table.
0023
Frequency reference
According to the set value in n152.
0024
Output frequency
According to the set value in n152.
0025 to 0026
Not used
---
0027
Output current
Read based on 1 A as 10.
0028
Output voltage
Read based on 1 V as 1.
0029
Fault status (see note 2)
Refer to the following corresponding table.
002A
Warning (see note 2)
Refer to the following corresponding table.
002B
Input terminal status
Refer to the following corresponding table.
002C
Inverter status
Refer to the following corresponding table.
002D
Output terminal status
Refer to the following corresponding table.
002E
Refer to the following corresponding table.
002F to 0030
not used
---
0031
Main circuit DC voltage
Read based on 1 V as 1.
0032
Torque reference
Read based on
±
1% as
±
1 and the rated
motor torque is 100%.
0033 to 0034
Not used
---
0035
Read based on 1 [h] as 1
0036
Not used
---
0037
Output power
Read based on
±
1 kW as
±
100.
0038
PID feedback
Read based on 1% as 10 and a value
equivalent to the maximum frequency as
100%.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...