![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836032.webp)
2-9
H
Removing the Terminal Cover
D
0.2- to 3.7-kW Inverters
·
After the front cover is removed, press the left and right sides of the terminal cover in
the arrow 1 directions and lift the terminal cover in the arrow 2 direction as shown in the
following illustration.
D
5.5-/7.5-kW Inverters
·
Loosen the terminal cover screws in the direction of arrows 1.
·
Press the left and right sides of the terminal cover in the direction of arrows 2 and lift it in
the direction of arrow 3 as shown in the following illustration.
Note
None of the following 200-V models have a terminal cover. Instead, the front
cover is used as a terminal cover.
3G3MV-A2001 (0.1 kW), 3G3MV-A2002 (0.2 kW), 3G3MV-A2004 (0.4 kW),
3G3MV-A2007 (0.75 kW), 3G3MV-AB001 (0.1 kW), 3G3MV-AB002 (0.2 kW),
and 3G3MV-AB004 (0.4 kW)