![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836169.webp)
6-27
Note
The carrier frequency changes as shown in the following graph with 7 through 9
set in n46.
Carrier Frequency (n080: 7 through 9)
Carrier
Frequency
83.3 Hz (Set value: 7)
41.6 Hz (Set value: 8)
27.7 Hz (Set value: 9)
208.3 Hz (Set value: 7)
104.1 Hz (Set value: 8)
69.4 Hz (Set value: 9)
Output frequency
·
The Inverter cannot maintain rated output current with the carrier frequency set to a
value higher than the default one.
The following table shows the default settings and the reduced rated inverter output
currents resulting from a higher setting for the carrier frequency for each Inverter
model.
When the carrier frequency is set to a higher value than the default setting, use the
Inverter at a current less than the reduced rated output current.
Voltage
Model
3G3MV-
Default
setting
Rated
output
current (A)
Set to 3
Reduced
rated output
current (A)
Set to 4
Reduced
rated output
current (A)
3-phase
200 V
A2001
4 (10 kHz)
0.8
¬
¬
3-phase
200 V
A2002
4 (10 kHz)
1.6
¬
¬
A2004
4 (10 kHz)
3.0
¬
¬
A2007
4 (10 kHz)
5.0
¬
¬
A2015
3 (7.5 kHz)
8.0
¬
7.0
A2022
3 (7.5 kHz)
11.0
¬
10.0
A2040
3 (7.5 kHz)
17.5
¬
16.5
A2055
3 (7.5 kHz)
25
¬
23
A2075
3 (7.5 kHz)
33
¬
30
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...