3-8
Note 1.
The setting unit of the frequency reference and output frequency is determined
by the set value in n035. The default unit is Hz.
Note 2.
The output power monitor is not displayed in vector control mode. ’--------’ is
displayed instead
Note 3.
This function is provided for 200-- and 400--V (5.5/7.5kW) inverters only.
H
Example of Forward/Reverse Selection Settings
Key
sequence
Indicator
Display
example
Explanation
Press the Mode Key repeatedly until the F/R
indicator is lit.
The present setting will be displayed.
For: Forward; rEv: Reverse
Use the Increment or Decrement Key to
change the direction of motor rotation. The
direction of motor rotation selected will be
enabled when the display changes after the
key is pressed.
Note
The direction of motor rotation can be changed, even during operation.
H
Example of Local/Remote Selection Settings
Key
sequence
Indicator
Display
example
Explanation
Press the Mode Key repeatedly until the
LO/RE indicator is lit.
The present setting will be displayed.
rE: Remote; Lo: Local
Use the Increment or Decrement Key to set
the Inverter to local or remote mode. The
selection will be enabled when the display
changes after the key is pressed.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...