Wiring the Power Supply
Make sure that the Inverter and Noise Filter are grounded together.
·
Always connect the power input terminals (R/L1, S/L2, and T/L3) and power supply via
a dedicated Noise Filter.
·
Reduce the length of the ground wire as much as possible.
·
Locate the Noise Filter as close as possible to the Inverter. Make sure that the cable
length between the Noise Filter and the Inverter does not exceed 40 cm.
·
The following Noise Filters are available (all footprint type).
3-phase 200-VAC Noise Filter
Inverter
3-phase 200-VAC Noise Filter
Model 3G3MV-
Model 3G3MV-
Rated current (A)
A2001/A2002/A2004/A2007 PFI2010-E
10
A2015/A2022
PFI2020-E
16 to 20
A2040
PFI2030-E
26 to 30
A2055/A2075
PFI2050--E
50
Single-phase 200-VAC Noise Filter
Inverter
Single-phase 200-VAC Noise Filter
Model 3G3MV-
Model 3G3MV-
Rated current (A)
AB001/AB002/AB004
PFI1010-E
10
AB007/AB015
PFI1020-E
20
AB022
PFI1030-E
30
AB040
PFI1040-E
40
3-phase 400-VAC Noise Filter
Inverter
3-phase 400-VAC Noise Filter
Model 3G3MV-
Model 3G3MV-
Rated current (A)
A4002/A4004
PFI3005-E
5
A4007/A4015/A4022
PFI3010-E
10
A4030/A4040
PFI3020-E
15 to 20
A4055/A4075
PFI3030--E
30
Design
Chapter 2
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...