1-7
Appearance
Function
Name
PRGM indicator
The parameters in n001 through n179 can be set
or monitored while this indicator is lit.
Note
While the Inverter is in operation, the
parameters can be only monitored and only
some parameters can be changed. Any
RUN command input is ignored while this
indicator is lit. Unless n001 is 5.
Mode Key
Switches the simplified-LED (setting and
monitor) item indicators in sequence.
Parameter being set will be canceled if this key is
pressed before entering the setting.
Increment Key
Increases multi-function monitor numbers,
parameter numbers, and parameter set values.
Decrement Key
Decreases multi-function monitor numbers,
parameter numbers, and parameter set values.
Enter Key
Enters multi-function monitor numbers,
parameter numbers, and internal data values
after they are set or changed.
RUN Key
Starts the Inverter running when the 3G3MV is in
operation with the Digital Operator.
STOP/RESET Key
Stops the Inverter unless parameter n007 is set
to disable the STOP Key. Functions as a Reset
Key when an inverter error occurs (see note).
Note
For safety reasons, the reset will not work while a RUN command (forward or reverse) is in effect.
Wait until the RUN command is OFF before resetting the Inverter.
Overview
Chapter 1
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...