6-40
Note
If set to vector control mode, the default value will be 0.2.
Set Values
·
This parameter is used for the response adjustment of the slip compensation function.
·
The default setting does not need any changes in normal operation.
·
Change the default setting in the following cases.
The motor vibrates:
Set the value to a larger value.
The motor response is low:
Set the value to a smaller value.
n113
Slip Compensation During
Regeneration
Register
0171
Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Set Values
Value
Description
0
Slip compensation function disabled during regeneration
1
Slip compensation function enabled during regeneration
·
Select whether the slip compensation function is enabled or not, even during regen-
eration (i.e.: when regeneration energy is returning during deceleration, etc.).
·
This parameter is only enabled in vector control mode. (In V/f control mode, the slip
compensation function will be disabled during regeneration, regardless of the setting
for this parameter.)
Advanced Operation
Chapter 6
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...