![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836114.webp)
5-15
·
Set the frequency of minimum analog input (0 V, 0 mA, or 4 mA) in n42 as percentage
based on the maximum frequency as 100%.
Example: In order to obtain 50% maximum frequency output with 0 V input, set the
value to 50%.
n060
Frequency Reference Gain
Register
013C
Hex
Changes during
operation
Yes
Setting
range
0% to 255%
(Max. frequency = 100%)
Unit of
setting
1%
Default setting
100
n061
Frequency Reference Bias
Register
013D
Hex
Changes during
operation
Yes
Setting
range
--99% to 99%
(Max. frequency = 100%)
Unit of
setting
1%
Default setting
0
D
Filter Time Constant Settings (n062)
·
A primary delay digital filter can be set for analog frequency references to be input.
·
This setting is ideal if the analog input signal changes rapidly or the signal is subject to
noise interference.
·
The larger the set value is, the slower the response speed will be.
n062
Analog Frequency Reference
Filter Time
Register
013E
Hex
Changes during
operation
No
Setting
range
0.00 to 2.00 (s)
Unit of
setting
0.01 s
Default setting
0.10
H
Multi-function Analog Input
An auxiliary analog input can be set for the Digital Operator’s multi-function analog volt-
age/current input. Select from the following functions.
n077
Multi-function Analog Input
Terminal Function Selection
Register
014D
Hex
Changes during
operation
No
Setting
range
0 to 4
Unit of
setting
1
Default setting
0
n078
Multi-function Analog Input
Terminal Selection
Register
014E
Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
n079
Multi-function Analog Input
Frequency Bias
Register
014F
Hex
Changes during
operation
No
Setting
range
0 to 50
Unit of
setting
1 %
Default setting
10
Note
Please also refer to page 2-20.
Basic Operation
Chapter 5
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...