3-2 Parameter Copy and Verify Function
The Digital Operator of the 3G3MV Inverter has an EEPROM in which the
set values in all the parameters and data on the capacity and software ver-
sion of the Inverter can be stored.
By using the EEPROM, most parameter set values in the Inverter can be
copied to another Inverter.
Note
In the above case, however, the Inverters must have the same power supply
specification and control mode (i.e., V/f or vector control mode). Some types of
parameter set values cannot be copied.
3-2-1 Parameter for Copying and Verifying Set Values
·
Use the following parameter to read, copy, and verify the set values.
Parame-
ter
Register
Name
Description
Setting
range
Unit of
setting
Default
setting
Chan-
ges dur-
ing
opera-
tion
n176
01B0
Parame-
ter copy
and
verify
function
selection
The following items are
selectable.
rdy: Ready to accept the
next command
rEd: Reads the parameter
CPy: Copies the parameter
vFy: Verifies the parameter
vA: Displays the capacity of
the Inverter
Sno: Displays the software
version.
rdy to
Sno
---
rdy
OK
Note
No value can be copied or written while the Inverter is in operation.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...