10-21
Para
me-
ter
No.
Ref-
er-
ence
page
Chan-
ges dur-
ing
opera-
tion
Defaul
t set-
ting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Reg-
ister
No.
n108
016C Motor leak-
age induc-
tance
Set the leakage inductance of the motor in use.
Note
This parameter is used as a vector con-
trol constant.
Note
The Inverter with the default setting in this
parameter fully functions in vector con-
trol.
0.00
to
655.0
0.01
mH
Varies
with
the
capac-
ity.
No
6-2
n109
016D Torque
compensa-
tion limit
Set a limit on the torque compensation function
in vector control mode.
Note
Normally, the default setting does not
need to be changed.
Note
The Inverter in torque compensation con-
trol limits the torque at a current 1.5 times
larger than the set value.
0 to
250
1%
150
No
6-3
n110
016E Motor no-
load cur-
rent
Used to set the no-load current of the motor in
use based on the rated motor current as 100%.
Note
Used as the constant of vector control
and the slip compensation function.
0 to
99
1%
Varies
with
the
capac-
ity
No
5-6
n111
016F Slip com-
pensation
gain
Used to set the gain of the slip compensation
function.
Note
The default is set to 1.0 in vector control
mode.
Note
The slip compensation function is dis-
abled with n66 set to 0.0.
0.0 to
2.5
0.1
0.0
Yes
6-39
n112
0170
Slip com-
pensation
primary
delay time
Used for the response speed of the slip
compensation function.
Note
The default is set to 0.2 in vector control
mode.
Note
The default setting does not need any
changes in normal operation.
0.0 to
25.5
0.1 s
2.0
No
6-39
n113
0164
Slip com-
pensation
during
regenera-
tion
Selects the slip compensation function in
regenerative operation.
0: Disabled
1: Enabled
Note
This parameter is valid only in vector con-
trol mode.
0, 1
1
0
No
6-40
n114
Not used
---
---
---
---
---
---
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...