![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836313.webp)
10-3
Param-
eter
No.
Ref-
er-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Regis-
ter No.
n002
0102
Control mode
selection
Used to select the control mode of the
Inverter.
0: V/f control mode
1: Vector control mode (open loop)
Note
The set value in n002 is not ini-
tialized with n001 set to 8 or 9.
Note
Each of the following parame-
ters is initialized according to
the preset control mode. The
default setting varies with the
control mode.
n014: Middle output frequency
n015: Middle output frequency volt-
age
n016: Minimum output frequency
n017: Minimum output frequency
voltage
n104: Torque compensation primary
delay time constant
n111: Slip compensation gain
n112: Slip compensation primary
delay time constant
See the reference pages for details.
0, 1
1
0
No
5-3
n003
0103
Operation
command
selection
Used to select the input method for
the RUN and STOP commands in
remote mode.
0: The STOP/RESET Key on the digi-
tal Operator is enabled.
1: Multi-function input is enabled
through the control circuit terminals
in 2- or 3-wire sequence.
2: RS-422/485 communications are
enabled.
3: Input is enabled from the optional
CompoBus/D Communications
Unit.
Note
The RUN command only
through key sequences on the
Digital Operator is acceptable
in local mode.
0 to 3
1
0
No
5-11
List of Parameters
Chapter 10
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...