![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mv-a2002/sysdrive-3g3mv-a2002_user-manual_742836079.webp)
3-11
H
Sequence of Display
Reading
Completed
reading
or
Writing
Completed
writing
or
Verifying
Completed
verifying
or
Inverter
capacity
Software
version
or
or
Note
The following display is an example of the capacity displayed.
Voltage class
2: 3-phase 200 V
b: Single-phase 200 V
4: Three-phase 400 V
Max. applicable motor capacity
0.1: 0.1 kW
0.2: 0.25 kW/0.37 kW
0.4: 0.55 kW
0.7: 1.1 kW
1.5: 1.5 kW
2.2: 2.2 kW
3.0: 3.0 kW
4.0: 4.0 kW
5.5: 5.5 kW
7.5: 7.5kW
3-2-2 Parameter Copying Procedure
·
To copy parameter values to another Inverter, take the following steps.
1. Set n001 for parameter write-prohibit selection/parameter initialization to 4.
2. Set n177 for parameter read-prohibit selection to 1 so that the parameters can be
read.
3. Read the parameter set value with the EEPROM of the Digital Operator with the item
rED selected.
4. Turn OFF the Inverter and remove the Digital Operator.
5. Mount the Digital Operator to the Inverter to which the parameters are to be copied.
Then turn ON the Inverter.
6. Copy the data in the EEPROM to the Inverter with the item CPy selected.
7. Check that the data is written correctly with the item vFy selected.
Preparing for Operation and Monitoring
Chapter 3
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...