[10] + [00] + [01] + [00] + [02]
Set the constants contained in the DSR message.
Use
Set Constant
and set the constants in Hex.
<I>
The length is set in the length box. Insert the length by using the
Insert
icon. The
length is the number of bytes of the succeeding data (R(3N + 3), 4). The length is
automatically set by the CX-Protocol.
(R(3N+3), 4)
The Inverter’s actual data to be sent. This example selects
Variable
and
Read R()
and sets the operand. Set
Data
to 3N + 3 because the RUN command data uses four
bytes each from S + 3, S + 6, and S + 9.
Set
Data Size
to 0N + 4 so that it will be set to four bytes.
<c>
The check code is set in the check code box. Insert the check code by using the
Insert
icon. All the data including the address data before the check code is oper-
ated. Mark all the items if the Protocol Support Tool is used. The check code is auto-
matically set by the CX-Protocol.
·
DSR Message to Read the Inverter Status
The DSR message to read the Inverter status from register 002C Hex consists of the
following items.
CRC-16 check (Set with <c>)
Number of read data registers: 1
Read start register number (Inverter status: 002C)
Function code (Read 03)
Slave address (Set with <a>)
Set data: <a> + [03] + [00] + [2C] + [00] + [01] + <c>
Set the address data, constant data, and check code data.
H
Recv Message Detail Settings
1. With the left button of the mouse, click on
List of Recv Messages
. Then click on a
blank space with the right button of the mouse.
2. Select
New
and
Recv Message
.
The following table will appear. Set the send message in the table.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...