7-49
Note
The CRC-16 check code is used for communications with the 3G3MV. Select the
CRC-16 check code and set the initial value to 65535.
Select
Reverse
for the conversion method. Then select
BIN
.
Length (l)
Set the length of the data.
Note
All communications with the 3G3MV are performed in byte units. Select
1 Byte
and
BIN
. Select
No
for reading data because there is no data to be read.
Address (a)
Set the addresses of the Slaves.
Note
In this example, the Slave addresses are set in S + 2, S + 5, and S + 8. Therefore,
retrieve the data from those locations.
The address is set in the LSB of each word. To read the byte, select
Variable
(Reverse)
, otherwise the data is read from the LSB. Then click on
Execute
Address
with the left button of the mouse.
Select
Read R ()
and set
Data/Address
to the operand (3N + 2) using the number
(N) of times to repeat the step.
Set
Data Size
to 1 byte as a default. If the default value has been changed, set it to
0N + 1.
Data
Set the DSR message in details.
·
DSR Message Requesting that the RUN Command and Frequency Reference be
Written
The DSR message to write data to two registers from register 0001 Hex (the RUN com-
mand) consists of the following items.
CRC-16 check (Set with <c>)
Set with variables
Next register data
Start register data
Number of bytes of attached data (set with <l>)
Number of write data registers: 2
Write start register number (RUN command: 0001)
Function code (Write 10)
Slave address (Set with <a>)
Set data: <a> + [10] + [00] + [01] + [00] + [02] + <I> + (R (3N + 3), 4) + <c>
<a>
The Slave address is set in the address box. Insert the address with the
Insert
icon.
Communications
Chapter 7
Summary of Contents for SYSDRIVE 3G3MV A2002
Page 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Page 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Page 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Page 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Page 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Page 311: ...Chapter 10 List of Parameters 10...
Page 342: ...Chapter 11 Using the Inverter for a Motor 11...
Page 348: ...Appendix A Standard Models...